Home
Download PDF
Order CD-ROM
Order in Print
Home
>
Cold Research and Engineering Laboratory Reports
>
> TR02-1(ERDC-CRL)
Guide for Characterization of Sites Contaminated with Energetic Materials
CONTENTS - TR02-1ERDC-CRL0005
TABLES - TR02-1ERDC-CRL0006
ABBREVIATIONS - TR02-1ERDC-CRL0007
BACKGROUND - TR02-1ERDC-CRL0008
Definition of Energetic Materials
Table 1. Physical and chemical properties of nitroaromatics and nitramines
Definition of Energetic Materials - continued
Range Types Classification
SAMPLING
Sample Collection - TR02-1ERDC-CRL0014
Other Co-contaminants
Atmospheric Impact
SAMPLE PRESERVATION, EXTRACTION, AND ANALYSIS
Table 2. Detection limits for explosives in soil (mg/kg)
Field Screening Methods
ENVIRONMENTAL FATE OF EXPLOSIVES
ENVIRONMENTAL FATE OF EXPLOSIVES - continued
SUMMARY - TR02-1ERDC-CRL0022
LITERATURE CITED - TR02-1ERDC-CRL0023
LITERATURE CITED - continued - TR02-1ERDC-CRL0024
LITERATURE CITED - continued - TR02-1ERDC-CRL0025
LITERATURE CITED - continued - TR02-1ERDC-CRL0026
LITERATURE CITED - continued - TR02-1ERDC-CRL0027
LITERATURE CITED - continued - TR02-1ERDC-CRL0028
LITERATURE CITED - continued - TR02-1ERDC-CRL0029
APPENDIX A: SAFETY PROCEDURE
APPENDIX A: SAFETY PROCEDURE - continued - TR02-1ERDC-CRL0031
APPENDIX A: SAFETY PROCEDURE - continued - TR02-1ERDC-CRL0032
Toxicity Associated with Explosives
Toxicity Associated with Explosives - continued
APPENDIX B: SOIL SAMPLING
Soil Sample Mixing and Subsampling
Sampling Strategy - TR02-1ERDC-CRL0037
Sampling Strategy - continued
APPENDIX C: GROUNDWATER SAMPLING
APPENDIX C: GROUNDWATER SAMPLING - conitnue
APPENDIX C: GROUNDWATER SAMPLING - continued
APPENDIX D: BOREHOLE DRILLING
Monitoring Well Installation
APPENDIX E: SAMPLE CONSERVATION: MAXIMUM HOLDING TIMES
APPENDIX F: EXTRACTION AND ANALYSIS: EPA METHOD 8330/8095
WATER EXTRACTION BY SALTING OUT
APPENDIX G: SOLID-PHASE CARTRIDGE EXTRACTION
APPENDIX H: COLORIMETRIC FIELD METHODS
Visual Colorimetric Screening Method
Spectrophotometric Colorimetric Methods Extraction
RDX On-Site Determination
Table H2. Detection limits, colorimetric method
APPENDIX I: GAS CHROMATOGRAPHY FIELD METHOD
Calibration Standards - TR02-1ERDC-CRL0054
APPENDIX J: ENZYME IMMUNOASSAY FIELD METHOD
Advantages and Limitations of EIA Field Screening
REPORT DOCUMENTATION PAGE - TR02-1ERDC-CRL0057
TR02-1(ERDC-CRL)