Form Approved
REPORT DOCUMENTATION PAGE
OMB No. 0704-0188
Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and
maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information,
including suggestion for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington,
VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503.
1. AGENCY USE ONLY (Leave blank)
2. REPORT DATE
3. REPORT TYPE AND DATES COVERED
October 1997
4. TITLE AND SUBTITLE
5. FUNDING NUMBERS
Decontaminating Groundwater Sampling Devices
6. AUTHORS
Louise V. Parker and Thomas A. Ranney
7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES)
8. PERFORMING ORGANIZATION
REPORT NUMBER
U.S. Army Cold Regions Research and Engineering Laboratory
72 Lyme Road
Special Report 97-25
Hanover, New Hampshire 03755-1290
9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES)
10. SPONSORING/MONITORING
AGENCY REPORT NUMBER
U.S. Army Environmental Center
Aberdeen Proving Ground, Maryland 21010-5401
SFIM-AEC-ET-CR-97021
11. SUPPLEMENTARY NOTES
For conversion of SI units to non-SI units of measurement, consult ASTM Standard E380-93, Standard Practice for Use of the
International System of Units, published by the American Society for Testing and Materials, 1916 Race St., Philadelphia, Pa.
19103.
12a. DISTRIBUTION/AVAILABILITY STATEMENT
12b. DISTRIBUTION CODE
Approved for public release; distribution is unlimited.
Available from NTIS, Springfield, Virginia 22161
13. ABSTRACT (Maximum 200 words)
These studies are the second part of a two-year project that examines decontaminating groundwater sampling
devices. In the first year, the efficiency of various decontamination protocols was tested using small test pieces
of materials that are commonly used in groundwater sampling devices. Those tests showed that a hot detergent
wash and rinse followed by hot air drying (105C) was the most effective decontamination protocol. In these
studies, two groundwater sampling devices, a bailer and a bladder pump, were used to sample groundwater
that was contaminated with either trichloroethylene (TCE), munitions, or pesticides. These studies showed that
a hot detergent wash and hot water rinse followed by hot air drying is an effective method for decontaminating
these sampling devices.
14. SUBJECT TERMS
15. NUMBER OF PAGES
28
Bailers
Decontamination
Groundwater-sampling pumps
16. PRICE CODE
Cleaning
Groundwater sampling devices
17. SECURITY CLASSIFICATION
18. SECURITY CLASSIFICATION
19. SECURITY CLASSIFICATION
20. LIMITATION OF ABSTRACT
OF REPORT
OF THIS PAGE
OF ABSTRACT
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED
UL
Standard Form 298 (Rev. 2-89)
Prescribed by ANSI Std. Z39-18
298-102