Extreme ice thicknesses from freezing rain
Final Report
References
ASCE, in draft, Minimum Design Loads for Buildings and Other Structures, ASCE Standard 7-
05, Reston, Virginia.
ASCE, 2003, Minimum Design Loads for Buildings and Other Structures, ASCE Standard 7-02,
Reston, Virginia.
ASCE, 1991, Guidelines for Electrical Transmission Line Structural Loading, ASCE Manual 74,
American Society of Civil Engineers, New York.
Bennett, I., 1959, Glaze: its meteorology and climatology, geographical distribution, and
economic effects, Quartermaster Research and Engineering Center, Technical Report EP-105,
217 pages.
Changnon, S., 2003, Characteristics of ice storms in the United States, J. of Applied
Meteorology, 42, 630-639.
Golikova, T.N., B.F. Golikov and D.S. Savvaitov, 1983, Methods of calculating ice loads on
overhead lines as spatial constructions, Proceedings of the First International Workshop on
Atmospheric Icing of Structures, CRREL Special Report 83-17, pp 341-346.
Hay, W.W., 1957, Effects of ice storms on railroad transportation, The effect of weather on
railroad operation, maintenance, and construction, Geography Department, U. of Illinois at
Urbana Champaign, pp 88-117.
Jones, K.F., 1996, Ice accretion in freezing rain, CRREL Report 96-2,
http://www.crrel.usace.army.mil/techpub/CRREL_Reports/reports/CR96_02.pdf
Jones, K.F., 1998, A simple model for freezing rain ice loads, Atmospheric Research, pp 87-97.
ftp://ftp.crrel.usace.army.mil/pub/outgoing/kjones/SimpleModel.pdf
Jones, K.F., R. Thorkildson and J.N. Lott, 2002, The development of the map of extreme ice
loads for ASCE Manual 74, Electrical Transmission in a New Age, Omaha, ASCE, Reston
Virginia, pp 9-31. Published on the web as The development of a U.S. climatology of extreme
ice loads at ftp://ftp.ncdc.noaa.gov/pub/data/techrpts/tr200201/tr2002-01.pdf
Jones, K.F. and H.B. White, 2002, The estimation and application of extremes, Electrical
Transmission in a New Age, Omaha, ASCE, Reston Virginia, pp 32-47.
ftp://ftp.crrel.usace.army.mil/pub/outgoing/kjones/ETNAjonesandwhite.pdf
NESC, 1997, National Electrical Safety Code, National Bureau of Standards, Washington, D.C.
NOAA, 1950-1958, Climatological Data, National Summary, National Climate Data Center,
Asheville, North Carolina
NOAA, 1959-present, Storm Data, National Climate Data Center, Asheville, North Carolina.
Rawlins, 1979, "Galloping of conductors", chapter 4 in Transmission Line Reference Book,
Electrical Power Research Institute.
Twisdale, L.A., 1982, Wind-loading underestimate in transmission line design, Transmission and
Distribution, December 1982, pp 40-45.
September 2004
Page 11